logo
Products
PRODUCTS DETAILS
Home > Products >
HVLS Fan Energy-saving Ventilation And Cooling Equipment For Factories

HVLS Fan Energy-saving Ventilation And Cooling Equipment For Factories

MOQ: 1Pcs
Price: 300-500 usd
Standard Packaging: With regular Film and Carton
Delivery Period: 7 work days
Payment Method: T/T
Supply Capacity: 500PCS/Mons
Detail Information
Place of Origin
China
Brand Name
PK
Certification
CE,ISO,SGS
Model Number
PK-AC112
Material:
Aluminum Alloy
Air Flow (m³/min):
5000 M³ / Min
Power​:
230 W
Voltage​:
220V
Weight:
27 KG
Noise:
38 Db
Blade Diameter:
3.5 M
Number Of Blades:
6 Pieces
Highlight:

HVLS fan for factories

,

energy-saving ventilation fan

,

industrial high volume fan

Product Description

**Industrial HVLS Ceiling Fan – Low-Speed, Large-Diameter Energy-Efficient Air Circulation and Cooling for Factories, Warehouses and High-Ceiling Spaces**

## Product Description

This industrial HVLS (High-Volume, Low-Speed) ceiling fan is a large-diameter air circulation system engineered for tall, expansive spaces such as factories, warehouses and logistics hubs. Unlike conventional high-speed fans, it operates on a low-speed, large-diameter principle: a permanent-magnet synchronous motor (PMSM) drives aerodynamically profiled blades—commonly aviation-grade aluminum or aluminum-magnesium alloy—at roughly 50–60 rpm, pushing a massive volume of air downward in a slow, wide column rather than a concentrated jet. This creates a gentle, natural-feeling breeze across the entire floor area, improving air circulation, reducing heat stress and helping equalize temperature stratification in high-ceiling buildings.

Representative commercial models span diameters from approximately 5.5 m to 8.2 m, with motor power ratings from roughly 1.2 kW to 1.8 kW. At the largest end, an 8.2 m unit delivers around 18,300 m³/h of airflow at only 1.8 kW, covering an effective area of up to 1,200–1,500 m² depending on mounting height and layout. The fan is typically direct-drive, eliminating gearboxes and their associated oil changes, wear and maintenance. Safety features on industrial-grade models include Y-shaped safety clips, self-locking nuts and multiple redundancy protections.

## Applicable Locations

  • Manufacturing workshops, assembly plants and machining floors
  • Warehouses, distribution centers and logistics facilities
  • Gymnasiums, sports halls and large public venues
  • Livestock and poultry sheds requiring gentle air movement
  • Exhibition halls, stations and other tall-ceiling public buildings

## Product Parameter

Representative specifications from commercially available HVLS industrial fans. Actual parameters vary by model, diameter and configuration.

Item 5.5 m Class 7.3 m Class (Representative PMSM Model) 8.2 m Class (PMSM Direct Drive)
Blade Diameter Approx. 5.5 m 7,300 mm 8,200 mm
Rated Power Approx. 1.2–1.3 kW 1.5 kW 1.8 kW
Rotating Speed Approx. 58–60 rpm 54–60 rpm 54 rpm
Rated Airflow Approx. 14,000 m³/h class 15,200–18,300 m³/h class 18,300 m³/h
Power Supply 220V / 380V 380V 380V
Blade Material Aluminum alloy / aluminum-magnesium alloy Metal / aviation-grade aluminum alloy Aviation-grade aluminum alloy 6063-T6
Effective Coverage Area Approx. 600–700 m² Approx. 1,000–1,200 m² Approx. 1,200–1,500 m²
Noise Level Approx. 45–55 dB(A) ≤ 40–55 dB(A) Approx. 45–55 dB(A)
Applicable Ceiling Height Above 4 m Above 4 m 6–20 m

*Note: Airflow units vary among commercial product listings (m³/h and m³/min). The table uses values explicitly stated as m³/h or reasonable conversions. Final selection should be based on manufacturer operating-condition parameters.*

## Feature

The core operating principle is low-speed, high-volume air displacement. Rather than relying on high velocity to cool a small area, the large blades move a slow-moving air mass across the entire floor, producing a 1–3 m/s micro-breeze that enhances evaporative cooling on the skin without the drafty, uncomfortable sensation of high-speed fans. This makes the fan suitable for large open work zones where directed spot cooling is impractical.

Direct-drive PMSM construction, as found on current-generation industrial models, removes the gearbox entirely. This eliminates oil leakage, gear wear and the regular maintenance those components require. Contemporary units commonly achieve IE5-level motor efficiency, with system-level energy savings reported at 15–40% compared with conventional IE3 asynchronous motor configurations. A 1.5–1.8 kW motor operating continuously is notably economical relative to the air volume moved and the floor area covered.

The fan also serves a year-round function beyond summer cooling. In heated buildings, warm air stratifies near the ceiling; the slow downward airflow from the fan mixes upper and lower air layers, returning trapped heat to the occupied zone and reducing heating energy demand in winter. Aviation-grade aluminum or aluminum-magnesium blades, often heat-treated to 6063-T5/T6 specifications and dynamically balanced to ISO 1940 G2.5 or better, provide corrosion resistance and long service life in humid or industrial atmospheres.

## Product Highlights

  • Low-speed, large-diameter design: 50–60 rpm moves a massive air volume to create full-area, natural-feeling airflow.
  • PMSM direct drive for high efficiency: gearbox-free construction avoids oil leakage and gear wear; IE5-class motor efficiency supports significant system energy savings.
  • Large coverage area: a single 7.3–8.2 m unit can cover approximately 1,000–1,500 m², suitable for tall workshops and warehouse spaces.
  • Year-round use: cools in summer and recirculates stratified warm air downward in winter to reduce heating energy consumption.
  • Aviation-grade blades and safety structure: aluminum/aluminum-magnesium alloy blades with high dynamic balance accuracy; Y-shaped safety clips, self-locking nuts and multiple safety designs.
  • Low-noise operation: unit noise typically controlled within 40–55 dB(A), suitable for working environments requiring continuous ventilation.
  • Low-maintenance direct-drive structure: significantly reduces mechanical maintenance points and supports long-term continuous operation.
Products
PRODUCTS DETAILS
HVLS Fan Energy-saving Ventilation And Cooling Equipment For Factories
MOQ: 1Pcs
Price: 300-500 usd
Standard Packaging: With regular Film and Carton
Delivery Period: 7 work days
Payment Method: T/T
Supply Capacity: 500PCS/Mons
Detail Information
Place of Origin
China
Brand Name
PK
Certification
CE,ISO,SGS
Model Number
PK-AC112
Material:
Aluminum Alloy
Air Flow (m³/min):
5000 M³ / Min
Power​:
230 W
Voltage​:
220V
Weight:
27 KG
Noise:
38 Db
Blade Diameter:
3.5 M
Number Of Blades:
6 Pieces
Minimum Order Quantity:
1Pcs
Price:
300-500 usd
Packaging Details:
With regular Film and Carton
Delivery Time:
7 work days
Payment Terms:
T/T
Supply Ability:
500PCS/Mons
Highlight

HVLS fan for factories

,

energy-saving ventilation fan

,

industrial high volume fan

Product Description

**Industrial HVLS Ceiling Fan – Low-Speed, Large-Diameter Energy-Efficient Air Circulation and Cooling for Factories, Warehouses and High-Ceiling Spaces**

## Product Description

This industrial HVLS (High-Volume, Low-Speed) ceiling fan is a large-diameter air circulation system engineered for tall, expansive spaces such as factories, warehouses and logistics hubs. Unlike conventional high-speed fans, it operates on a low-speed, large-diameter principle: a permanent-magnet synchronous motor (PMSM) drives aerodynamically profiled blades—commonly aviation-grade aluminum or aluminum-magnesium alloy—at roughly 50–60 rpm, pushing a massive volume of air downward in a slow, wide column rather than a concentrated jet. This creates a gentle, natural-feeling breeze across the entire floor area, improving air circulation, reducing heat stress and helping equalize temperature stratification in high-ceiling buildings.

Representative commercial models span diameters from approximately 5.5 m to 8.2 m, with motor power ratings from roughly 1.2 kW to 1.8 kW. At the largest end, an 8.2 m unit delivers around 18,300 m³/h of airflow at only 1.8 kW, covering an effective area of up to 1,200–1,500 m² depending on mounting height and layout. The fan is typically direct-drive, eliminating gearboxes and their associated oil changes, wear and maintenance. Safety features on industrial-grade models include Y-shaped safety clips, self-locking nuts and multiple redundancy protections.

## Applicable Locations

  • Manufacturing workshops, assembly plants and machining floors
  • Warehouses, distribution centers and logistics facilities
  • Gymnasiums, sports halls and large public venues
  • Livestock and poultry sheds requiring gentle air movement
  • Exhibition halls, stations and other tall-ceiling public buildings

## Product Parameter

Representative specifications from commercially available HVLS industrial fans. Actual parameters vary by model, diameter and configuration.

Item 5.5 m Class 7.3 m Class (Representative PMSM Model) 8.2 m Class (PMSM Direct Drive)
Blade Diameter Approx. 5.5 m 7,300 mm 8,200 mm
Rated Power Approx. 1.2–1.3 kW 1.5 kW 1.8 kW
Rotating Speed Approx. 58–60 rpm 54–60 rpm 54 rpm
Rated Airflow Approx. 14,000 m³/h class 15,200–18,300 m³/h class 18,300 m³/h
Power Supply 220V / 380V 380V 380V
Blade Material Aluminum alloy / aluminum-magnesium alloy Metal / aviation-grade aluminum alloy Aviation-grade aluminum alloy 6063-T6
Effective Coverage Area Approx. 600–700 m² Approx. 1,000–1,200 m² Approx. 1,200–1,500 m²
Noise Level Approx. 45–55 dB(A) ≤ 40–55 dB(A) Approx. 45–55 dB(A)
Applicable Ceiling Height Above 4 m Above 4 m 6–20 m

*Note: Airflow units vary among commercial product listings (m³/h and m³/min). The table uses values explicitly stated as m³/h or reasonable conversions. Final selection should be based on manufacturer operating-condition parameters.*

## Feature

The core operating principle is low-speed, high-volume air displacement. Rather than relying on high velocity to cool a small area, the large blades move a slow-moving air mass across the entire floor, producing a 1–3 m/s micro-breeze that enhances evaporative cooling on the skin without the drafty, uncomfortable sensation of high-speed fans. This makes the fan suitable for large open work zones where directed spot cooling is impractical.

Direct-drive PMSM construction, as found on current-generation industrial models, removes the gearbox entirely. This eliminates oil leakage, gear wear and the regular maintenance those components require. Contemporary units commonly achieve IE5-level motor efficiency, with system-level energy savings reported at 15–40% compared with conventional IE3 asynchronous motor configurations. A 1.5–1.8 kW motor operating continuously is notably economical relative to the air volume moved and the floor area covered.

The fan also serves a year-round function beyond summer cooling. In heated buildings, warm air stratifies near the ceiling; the slow downward airflow from the fan mixes upper and lower air layers, returning trapped heat to the occupied zone and reducing heating energy demand in winter. Aviation-grade aluminum or aluminum-magnesium blades, often heat-treated to 6063-T5/T6 specifications and dynamically balanced to ISO 1940 G2.5 or better, provide corrosion resistance and long service life in humid or industrial atmospheres.

## Product Highlights

  • Low-speed, large-diameter design: 50–60 rpm moves a massive air volume to create full-area, natural-feeling airflow.
  • PMSM direct drive for high efficiency: gearbox-free construction avoids oil leakage and gear wear; IE5-class motor efficiency supports significant system energy savings.
  • Large coverage area: a single 7.3–8.2 m unit can cover approximately 1,000–1,500 m², suitable for tall workshops and warehouse spaces.
  • Year-round use: cools in summer and recirculates stratified warm air downward in winter to reduce heating energy consumption.
  • Aviation-grade blades and safety structure: aluminum/aluminum-magnesium alloy blades with high dynamic balance accuracy; Y-shaped safety clips, self-locking nuts and multiple safety designs.
  • Low-noise operation: unit noise typically controlled within 40–55 dB(A), suitable for working environments requiring continuous ventilation.
  • Low-maintenance direct-drive structure: significantly reduces mechanical maintenance points and supports long-term continuous operation.