logo
products
PRODUCTS DETAILS
Home > Products >
Greenhouse FRP fan conical poultry farm fiberglass exhaust box Negative pressure fan

Greenhouse FRP fan conical poultry farm fiberglass exhaust box Negative pressure fan

MOQ: 1Pcs
Price: USD500-USD5000/SET
Standard Packaging: With regular Film and Carton
Delivery Period: 3 DAYS After Deposit
Payment Method: T/T,D/A,Western Union,MoneyGram
Supply Capacity: 1500SET/MONTH
Detail Information
Place of Origin
China
Brand Name
KC
Certification
CE,ISO,SGS
Model Number
1460×1460×580
Feature:
Workshops With High Temperatures
Hight:
590mm
Type:
CAD/CAM
Air Volume:
68000m³/h
Site:
1460×1460×580(mm)
Noise Level:
≤68dB
Color:
Silver
Product Description
Greenhouse FRP fan conical poultry farm fiberglass exhaust box Negative pressure fan
 
 
Product Name‌ Glass Fiber Cone Fan ‌Installation‌ Wall/Window Mounted
‌Type‌ Oil-Impregnated Bearing Axial Fan ‌Application‌ Livestock Farming, Warehouses, Poultry, Greenhouses
‌Brand‌ KC ‌Energy‌ Electric
‌Material‌ Plastic (Blade), Glass Fiber (Fan Body) ‌Warranty‌ 1 Year
‌Motor‌ 100% Copper ‌After-sales‌ Online Support
‌Voltage‌ 220v, 380v ‌OEM/ODM‌ Supported
‌Frequency‌ 50HZ/60HZ ‌Origin‌ China
‌Size‌ 1460×1460×580, 1260×1260×560 ‌MOQ‌ 5 Pieces
‌Keywords‌ FRP Exhaust Fan    
 
 
Essential Installation Precautions for PVC/Plastic Steel Negative Pressure Fans:
 
Proper installation is crucial for maximizing the performance and lifespan of PVC/plastic steel negative pressure fans. Adhering to the following precautions will ensure optimal results:
Airtight Sealing: The wall surrounding the fan unit must be completely sealed to prevent air leakage. Any gaps or cracks will compromise the effectiveness of the negative pressure system. Use appropriate sealing materials, such as caulk or foam sealant, to ensure an airtight connection between the fan and the wall.
 
 
Strategic Airflow Management:
 
The ideal installation configuration involves closing all doors and windows on the same wall as the fan and opening doors and windows on the opposite wall. This creates a direct and linear airflow path, maximizing the efficiency of the ventilation system.
 
 
Pre-Installation Inspection:
 
Before commencing installation, thoroughly inspect the fan unit for any signs of damage or defects. Ensure that all fasteners are securely tightened and that the fan blades rotate freely without obstruction.
 
 
Obstruction-Free Airflow:
 
When selecting the installation location, ensure that there are no significant obstructions within a 2.5-3 meter radius of the fan's air outlet.
 
 
Stable and Level Mounting:
 
The fan unit must be mounted on a stable and level surface to prevent vibration and ensure proper operation. Use shims or leveling feet to adjust the fan's position as needed.
 
 
Motor Alignment:
 
After installation, verify that the motor is properly aligned and that the drive belt (if applicable) is correctly tensioned.
 
 
Post-Installation Inspection:
 
After completing the installation, carefully inspect the fan unit for any remaining tools or debris. Manually rotate the fan blades to check for any rubbing or obstructions.
 
 
Operational Testing:
 
Before putting the fan into regular use, perform a trial run to ensure that it operates smoothly and quietly. If any unusual noises or vibrations are detected, immediately stop the fan and investigate the cause.
 
 
Product Description

 

‌Model‌ ‌Voltage (V/Hz)‌ ‌Power (W)‌ ‌Noise (dB)‌ ‌Speed (r/min)‌ ‌Airflow (m³/h)‌ ‌Blade Size (mm)‌ ‌Product Dimensions (mm)‌
KC-1660 380/220 1100 68 450 63000 1450 1660/1660/590
KC-1460 380/220 750 65 450 44500 1250 1460/1460/580
KC-1260 380/220 750 60 540 32000 1050 1260/1260/560
KC-1060 380/220 550 60 540 28000 850 1060/1060/500
KC-880 380/220 370 55 720 20000 650 850/850/480
KC-760 380/220 370 50 900 13000 530 760/760/440
KC-660 380/220 370 50 900 10000 430 660/660/440
KC-560 380/220 370 50 900 8000 330 560/560/430

 

Greenhouse FRP fan conical poultry farm fiberglass exhaust box Negative pressure fan 0

 

 

Frequently Asked Questions


Q: What is your minimum survey?
A: We accept small orders, but the shipping fee will be very high

 

Q: Can you open our own brand?
A: Yes, we can provide OEM/ODM services and label your products with logo.

 

Q: How is the quality of your products?
A: All products are produced strictly in accordance with international standards and have passed the CE certification, CCC certification and ISO9001:2008 international quality management system.

 

Q: Can you accept inspections from third-party testing agencies?
Yes of course. Our products have been inspected by a third-party testing agency authorized by customs. And obtained a complete inspection report.


 

 

 
products
PRODUCTS DETAILS
Greenhouse FRP fan conical poultry farm fiberglass exhaust box Negative pressure fan
MOQ: 1Pcs
Price: USD500-USD5000/SET
Standard Packaging: With regular Film and Carton
Delivery Period: 3 DAYS After Deposit
Payment Method: T/T,D/A,Western Union,MoneyGram
Supply Capacity: 1500SET/MONTH
Detail Information
Place of Origin
China
Brand Name
KC
Certification
CE,ISO,SGS
Model Number
1460×1460×580
Feature:
Workshops With High Temperatures
Hight:
590mm
Type:
CAD/CAM
Air Volume:
68000m³/h
Site:
1460×1460×580(mm)
Noise Level:
≤68dB
Color:
Silver
Minimum Order Quantity:
1Pcs
Price:
USD500-USD5000/SET
Packaging Details:
With regular Film and Carton
Delivery Time:
3 DAYS After Deposit
Payment Terms:
T/T,D/A,Western Union,MoneyGram
Supply Ability:
1500SET/MONTH
Product Description
Greenhouse FRP fan conical poultry farm fiberglass exhaust box Negative pressure fan
 
 
Product Name‌ Glass Fiber Cone Fan ‌Installation‌ Wall/Window Mounted
‌Type‌ Oil-Impregnated Bearing Axial Fan ‌Application‌ Livestock Farming, Warehouses, Poultry, Greenhouses
‌Brand‌ KC ‌Energy‌ Electric
‌Material‌ Plastic (Blade), Glass Fiber (Fan Body) ‌Warranty‌ 1 Year
‌Motor‌ 100% Copper ‌After-sales‌ Online Support
‌Voltage‌ 220v, 380v ‌OEM/ODM‌ Supported
‌Frequency‌ 50HZ/60HZ ‌Origin‌ China
‌Size‌ 1460×1460×580, 1260×1260×560 ‌MOQ‌ 5 Pieces
‌Keywords‌ FRP Exhaust Fan    
 
 
Essential Installation Precautions for PVC/Plastic Steel Negative Pressure Fans:
 
Proper installation is crucial for maximizing the performance and lifespan of PVC/plastic steel negative pressure fans. Adhering to the following precautions will ensure optimal results:
Airtight Sealing: The wall surrounding the fan unit must be completely sealed to prevent air leakage. Any gaps or cracks will compromise the effectiveness of the negative pressure system. Use appropriate sealing materials, such as caulk or foam sealant, to ensure an airtight connection between the fan and the wall.
 
 
Strategic Airflow Management:
 
The ideal installation configuration involves closing all doors and windows on the same wall as the fan and opening doors and windows on the opposite wall. This creates a direct and linear airflow path, maximizing the efficiency of the ventilation system.
 
 
Pre-Installation Inspection:
 
Before commencing installation, thoroughly inspect the fan unit for any signs of damage or defects. Ensure that all fasteners are securely tightened and that the fan blades rotate freely without obstruction.
 
 
Obstruction-Free Airflow:
 
When selecting the installation location, ensure that there are no significant obstructions within a 2.5-3 meter radius of the fan's air outlet.
 
 
Stable and Level Mounting:
 
The fan unit must be mounted on a stable and level surface to prevent vibration and ensure proper operation. Use shims or leveling feet to adjust the fan's position as needed.
 
 
Motor Alignment:
 
After installation, verify that the motor is properly aligned and that the drive belt (if applicable) is correctly tensioned.
 
 
Post-Installation Inspection:
 
After completing the installation, carefully inspect the fan unit for any remaining tools or debris. Manually rotate the fan blades to check for any rubbing or obstructions.
 
 
Operational Testing:
 
Before putting the fan into regular use, perform a trial run to ensure that it operates smoothly and quietly. If any unusual noises or vibrations are detected, immediately stop the fan and investigate the cause.
 
 
Product Description

 

‌Model‌ ‌Voltage (V/Hz)‌ ‌Power (W)‌ ‌Noise (dB)‌ ‌Speed (r/min)‌ ‌Airflow (m³/h)‌ ‌Blade Size (mm)‌ ‌Product Dimensions (mm)‌
KC-1660 380/220 1100 68 450 63000 1450 1660/1660/590
KC-1460 380/220 750 65 450 44500 1250 1460/1460/580
KC-1260 380/220 750 60 540 32000 1050 1260/1260/560
KC-1060 380/220 550 60 540 28000 850 1060/1060/500
KC-880 380/220 370 55 720 20000 650 850/850/480
KC-760 380/220 370 50 900 13000 530 760/760/440
KC-660 380/220 370 50 900 10000 430 660/660/440
KC-560 380/220 370 50 900 8000 330 560/560/430

 

Greenhouse FRP fan conical poultry farm fiberglass exhaust box Negative pressure fan 0

 

 

Frequently Asked Questions


Q: What is your minimum survey?
A: We accept small orders, but the shipping fee will be very high

 

Q: Can you open our own brand?
A: Yes, we can provide OEM/ODM services and label your products with logo.

 

Q: How is the quality of your products?
A: All products are produced strictly in accordance with international standards and have passed the CE certification, CCC certification and ISO9001:2008 international quality management system.

 

Q: Can you accept inspections from third-party testing agencies?
Yes of course. Our products have been inspected by a third-party testing agency authorized by customs. And obtained a complete inspection report.